FLRY-A
Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
CABLE CONSTRUCTION | TECHNICAL AND ELECTRICAL DATA | MECHANICAL DATA | |||||
PRODUCT CODE | CROSS SECTION (Cu) | STRANDED COPPER CONDUCTER (Cu) | INSULATION MATERIAL AND DIAMETER(mm ±0,03) | WALL THICKNESS min (mm) | APPROXIMATE WEIGHT (kg/km) | CONDUCTOR RESISTANCE | WORKING TEMPERATURE |
FA035 | 0,35 mm² | 7x0,26 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,3 | 0,20 | 5,00 | <54,4 Ω/km | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA050 | 0,50 mm² | 19x0,19 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,6 | 0,22 | 7,00 | <37,1 Ω/km | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA075 | 0,75 mm² | 19x0,23 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 1,9 | 0,24 | 9,00 | <24,7 Ω/km | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA100 | 1,00 mm² | 19x0,26 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 2,4 | 0,24 | 11,00 | <18,1 Ω/km | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA150 | 1,50 mm² | 19x0,32 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 2,4 | 0,24 | 16,00 | <12,7 Ω/km | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA200 | 2,00 mm² | 19x0,38 mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 2,8 | 0,28 | 22,00 | <9,42 Ω/km | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
FA250 | 2,50 mm² | 19x0,41, mm | PVC (according to ISO 6722-1, CLASS B and CLASS C) 3,0 | 0,28 | 26,00 | <7,6 Ω/km | -40 to +105°C (CLASS B) -40 to +125°C (CLASS C) |
PACKAGE: CONIC PACK OR CARTON PACKING (It change change depends on customer request) OUTER SHEAT COLORS: BLACK, BLUE, RED, YELLOW, GREEN |